Skip to main content

Special Timer

  • Special Timers of mitsubishi PLC comes with both functionality of TT and Done bit of TOFF and TON timers.

Special timer

  • Here STMR is the is the special timer function, To is the TON timer, K100 is the preset value(you can give K10,K200, etc depending upon of the preset you require), and M0 is the result of the timer.
  • here i have used memory address M0 to store result of timer, and in Special timer the next three consecutive memory addresses are automatically assigned to store TT and Done bits of timers.
  • Here M0 is used to store the Done bit of TOFF timer,M1 for the TT bit of TOFF timer, M2 for TT bit of the TON timer, and the last M3 bit is used to store both Done bits of TON ans TOFF timers(first it works as a done bit of the TON timer and then it works as a done bit of the TOFF timer).

Timing diagram for special timer.

Above fig. shows timing diagram of the special timer with timing diagram with preset value of 5 sec.


  • DN bit TOFF :- This bit is used, when we want to ON a output for a Input ON duration and a preset duration after a input is OFF.
  • TT of TOFF :- This bit is used when we want to On a Output for preset time duration after input gets OFF.
  • TT of TON :- This bit is used when we want to turn ON a Output for a preset time duration if Input time duration is more or equal to preset time duration.
  • DN of TON and TOFF last bit of special timer:- This bit is used when you wants to turn ON a Output after preset time duration if input time duration is more than preset value and turn OFF a Output after preset value, when input gets OFF.

Comments

Popular posts from this blog

Timers in Siemens PLC Simatic manager

Timer :- Timer is nothing but a specialized clock in a programming software used to count the preset time intervals. In   Siemens PLC we have various ty pes of timers as :- 1) S_PULSE(Pulse timer), 2) S_PEXT(Extended Pulse Timer), 3) S_ODT(On Delay Timer), 4) S_ODTS(Retentive On Delay Timer), 5) S_OFFDT(Off Delay Timer). You must find out another five instruction sets in Timer Block in Simatic Manager STEP 7 as :- -(SP) pulse timer coil, -(SE) extended pulse timer coil, -(SD) on delay timer coil, -(SS) retentive on delay timer coil, -(SF) off delay timer coil. 1) S_PULSE(Pulse timer) :- S_PULSE Timer   Above Fig Shows how to use this timer in programming software,in this fig i have used 5 sec as a preset value, If you want to change it replace the 5 with any duration you want in S5T# 5 S.    In S_PULSE timer if input to timer is ON then timer starts Counting time as well as we get the Output at the instant the input is made ON. In t...

HOW TO DOWNLOAD AND INSTALL WONDERWARE FOR WINDOWS 8,7,10.

##You can Download a ZIP file of the software From Below link. https://drive.google.com/file/d/159y8W0c_bw0vvf1DNDQ08_QsLZ9h2Tb1/view?usp=sharing 1 ) You Can Also Watch a Video Tutorial of it  below. 2) You can also read out steps from below :-

Bit Logic Instruction in Simatic manager

There are total 14 instructions under the bit logic instruction like NO contact, NC contact, SR flip-flop, RS flip-flop,invert power flow etc. lets see the detailed use of them.  A) Normally open contact :- Normally open contacts are closed when the bit value stored at the specific address is equal to 1 (one)(here the specific address refers to the address assigned to the NO contact), when we press the Normally open contact assigned to the specific address then it becomes functionally closed and we get supply. here in below fig. when we press the NO contact I0.0 then Output Q0.0 gets ON and when we release the input I0.0 then Output gets OFF. B)Normally Closed Contact :- Normally closed contacts are closed when the bit value stored at the specific add, i.e. the address assigned to the NC contact is equal to 0(zero). when we press the Normally closed contact assigned to the specific address then it becomes functionally open and supply is cuts off. NC contact wor...