Q3. The lamp should glow after a delay of 15 sec when start switch S1 is made ON. the lamp should remain in glowing condition till the start switch S1 is made ON. The lamp should go immediately OFF when start switch S1 is made OFF.


Fig. Q3.


  • In this problem we want to ON the lamp after a 15 sec when start switch S1 is continuously pressed and as soon as the start switch is released lamp should go OFF, so in solution for this we used the NO start contact in series with the TON timer with preset value 15 sec.
  • In next rung we have used the Done Bit NO contact of timer in series with the lamp Output coil, that is the lamp gets ON after 15 sec if we press and hold start button for more than 15 sec.
  • when the start button is released connection to the timer gets cut and timer gets in OFF condition.

Comments

Popular posts from this blog

Timers in Siemens PLC Simatic manager

Timer :- Timer is nothing but a specialized clock in a programming software used to count the preset time intervals. In   Siemens PLC we have various ty pes of timers as :- 1) S_PULSE(Pulse timer), 2) S_PEXT(Extended Pulse Timer), 3) S_ODT(On Delay Timer), 4) S_ODTS(Retentive On Delay Timer), 5) S_OFFDT(Off Delay Timer). You must find out another five instruction sets in Timer Block in Simatic Manager STEP 7 as :- -(SP) pulse timer coil, -(SE) extended pulse timer coil, -(SD) on delay timer coil, -(SS) retentive on delay timer coil, -(SF) off delay timer coil. 1) S_PULSE(Pulse timer) :- S_PULSE Timer   Above Fig Shows how to use this timer in programming software,in this fig i have used 5 sec as a preset value, If you want to change it replace the 5 with any duration you want in S5T# 5 S.    In S_PULSE timer if input to timer is ON then timer starts Counting time as well as we get the Output at the instant the input is made ON. In t...

HOW TO DOWNLOAD AND INSTALL WONDERWARE FOR WINDOWS 8,7,10.

##You can Download a ZIP file of the software From Below link. https://drive.google.com/file/d/159y8W0c_bw0vvf1DNDQ08_QsLZ9h2Tb1/view?usp=sharing 1 ) You Can Also Watch a Video Tutorial of it  below. 2) You can also read out steps from below :-

Bit Logic Instruction in Simatic manager

There are total 14 instructions under the bit logic instruction like NO contact, NC contact, SR flip-flop, RS flip-flop,invert power flow etc. lets see the detailed use of them.  A) Normally open contact :- Normally open contacts are closed when the bit value stored at the specific address is equal to 1 (one)(here the specific address refers to the address assigned to the NO contact), when we press the Normally open contact assigned to the specific address then it becomes functionally closed and we get supply. here in below fig. when we press the NO contact I0.0 then Output Q0.0 gets ON and when we release the input I0.0 then Output gets OFF. B)Normally Closed Contact :- Normally closed contacts are closed when the bit value stored at the specific add, i.e. the address assigned to the NC contact is equal to 0(zero). when we press the Normally closed contact assigned to the specific address then it becomes functionally open and supply is cuts off. NC contact wor...